Back to Casualty List | Search The Casualty Database
Precis File
SHIP NAME: Moldanger KEY: NUM. ENTRIES: 2
source CGMIX
type A
volume
material
dead 0
link

MOLDA; Loss of Electrical Power On: 9/7/2008 MISLE Activity Number: 3354262 Originating Unit: Sector Houston/Galveston MISLE Activity Owner: Commandant (CG-5453) MISLE Activity Controller: Commandant (CG-5453) MISLE Case Number: I. INCIDENT BRIEF Qualified Individual reported a loss of power while moored at Shell Deer Park. Chief Engineer identified the loss of power generation during discharge operations due to a trip of the main switchboard and AC breaker from #3 generator; while three generators were in manual load sharing heavy load. Exchanged timer relay and tested all systems in automatic with no further issues. Case closed no enforcement action to follow


source CTX
type C
volume
material
dead 0
link

There is no Molda in Equasis SIN or MSI. Assuming Moldanger which is the only tanker starting with Molda, but we could be wrong.